Fire protection

Installation of fire protection. Protection for steel structures, concrete and other.

Acoustics

The rooms offer mute, acoustic plaster and sound. Produkty firm Ecophon, Top Akustik i inne.

PUR foam and polyurea

We spray foam PUR opened and closed cell and polymer coatings - polyurea.

Insulation Slabs

Explore the benefits of professional insulation of floors. Warming we spray and by the classical method.

IGNIVER – Gypsum

Light, Firestop powder produced from gypsum, rozdrobionego vermiculite and special modifiers. The product is applied by means of spraying units. The material is non-toxic, harmless, non-corrosive and non-irritating. The dry mass is poured into a container machine, mixed with water, then under pressure is fed to a special hose spray nozzle. The material should be sprayed layers. Gotowa okładzina ogniochronna ma fakturę „baranka”. It can be smoothed out before drying or after drying paint.

Classes of fire resistance of building elements protected ground IGNIVER are based on the requirements of the standards: IN 13381-3 (concrete elements), EN13381-4 (steel elements) and IN 13381-5 (elements of concrete / steel components).

 

Main applications:

  • Steel structures of open and closed profiles
  • Elements of reinforced concrete structures
  • Reinforced concrete floors
  • Elements of ceramic materials-cement
  • Metal ducts

 

Product Benefits:

  • Very good fire-retardant
  • Very good adhesion
  • Low bulk density
  • Chemical Resistance
  • Biological corrosion resistance
  • High durability
  • Fast application
  • Tightness
  • The content of fine vermiculite provides mechanical strength
  • It has no harmful substances
  • It does not contain heavy metals
  • Friendly to the environment

Properties

Reference document

Value

Unit of measure

Type of product

IN 13279-1:2005

C5/20 (flame retardant plaster)

The density of the dry mix

± 10%

[kg/m3]

Density of hardened mass

± 10%

[kg/m3]

Setting time

± 15

[min]

Theoretical consumption of a

4

[kg/1 m2/1 cm]

Adhesion

NF-P-15-203-1

> 0,022

[N/mm2] dla blachy to betonu

Reaction to fire

IN 13501-1

A1

Thermal conductivity

IN 6946

l = 0,062

[W/m2 x K]

Smoke production

NF F16-101

F0 (does not emit dense and toxic smoke)

Fire resistance class

Fires – CR-235-13-AUPE

Fires – CR-238-13-AUPE

Fires – CR-240-13-AUPE

R(ITS)15 R(ITS)240

[min]

The thickness of coatings for fire protection

from 10 do 90

[mm]

Package

bag 20 kg

Storage time

months from date of manufacture

The optimum temperature of the air during spraying

from 5 do 45

[°C]

Print Friendly, PDF & Email