PUREX NG – 0440 – Polychem

PUREX NG 0440 This system of closed cell designed for external insulation of roofs. It is used in concrete screed in:

  • industrial halls,
  • magazines,
  • garages,
  • other places where there is an increased load on the ground.

 

PUREX NG 0440 in some cases it may also be used for internal insulation.

 

Dane techniczne:

Parameter

Data

Application

External shower Roof

Structure

A closed cell

Density [kg/m3]

60

Thermal conductivity [W/m×K]

0,024

The thickness of the insulation [mm]

20

Wear foam [kg/m2]

1,2

The total thermal resistance [m2×K/W]

0,83

Thermal resistance of 1 kg piany [m2K/W]

0,69

Compressive strength [kPa]

≥250

Water absorption by total immersion in the 48 h

< 3 %

Reaction to fire according to DIN 4102

B2

Reaction to fire according to EN 13501-1

Class E

– 50 do + 100

– 50 do + 100