Fire protection

Installation of fire protection. Protection for steel structures, concrete and other.

Acoustics

The rooms offer mute, acoustic plaster and sound. Produkty firm Ecophon, Top Akustik i inne.

PUR foam and polyurea

We spray foam PUR opened and closed cell and polymer coatings - polyurea.

Insulation Slabs

Explore the benefits of professional insulation of floors. Warming we spray and by the classical method.

TECNOFOAM G-2050 – Tecnopol

Product G-2050 składa się z polioli i izocyjanianu. The material allows for a foam having a density of 48-57 kg/m3, available free of substances harmful to the ozone layer. The system is ready to use without any admixtures. The ambient temperature during application must not fall below 5 ° C lub być wyższa niż 40 ° C. Podłoże powinno być czyste, search, a wilgotność względna powinna być mniejsza niż 80%.

Prior to application, do a little test adhesion to ensure good adhesion of the material. It is worth noting, the metal surfaces prior to the application should be primed with anti-corrosive primer. To avoid high material consumption wind speed at the time of application may not exceed 30 km/h.

Product Features:

Apparent density of the finished product

from 50 do 70

[kg/m3]

Przewodność cieplna:

0,033 ± 10%

(In / m • K) (UNE w 12667: 2002)

Thermal conductivity at 10 ° C

0,022 ± 10%

(In / m • K) (A 92202)

Compressive Strength 10% Compression:

> 350

[ kPa ]

modulus

> 9000

[ kPa ] (UNE w 826:1996)

Classification in the capacity of self extinguishing

self-extinguishing

UNE w 13501-1:2007 + A1: 2010)

Resistance classification of the roof to external fire

Broof (t1)

UNE-EN 13501-5

Reaction to fire:

Class: It

(UNE w 13501-1:2007 + A1: 2010)

Dimensional stability: In 70 º, 90% HR:

<4%

(UNE EN 104:1997)

At -20 °, HR 50%:

<1%

(UNE EN 104:1997)

Coefficient of water vapor diffusion resistance

86

[ m ]

The content of closed cells

95

[ % ]

Print Friendly, PDF & Email